INTRODUCTION TO GAS SENSOR
Features:
* High sensitivity to LPG, iso-butane, propane
* Small sensitivity to alcohol, smoke.
* Fast response.
* Stable and long life
* Simple drive circuit
Flex sensors are the sensors that change in resistance depending on the amount of bend on the sensor. They convert the change in bend to electrical resistance-the more the bend the more the resistance value. They are usually in the form of a thin strip from 1”=5” long that varies in resistance. They can be made uni-directional or bi-directional.
SPECIFICATIONS:
Standard work condition
Symbol
|
Parametername
|
Technical condition
|
Remarks
|
Vc
|
Circuitvoltage
|
5V±0.1
|
AC OR DC
|
VH
|
Heatingvoltage
|
5V±0.1
|
ACOR DC
|
PL
|
Loadresistance
|
20KΩ
| |
RH
|
Heaterresistance
|
33Ω±5%
|
Room Tem
|
PH
|
Heatingconsumption
|
less than 750mw
|
Environment condition
Symbol
|
Parameter name
|
Technical condition
|
Remarks
|
Tao
|
Using Tem
|
-10℃-50℃
| |
Tas
|
Storage Tem
|
-20℃-70℃
| |
RH
|
Related humidity
|
less than 95%Rh
| |
O2
|
Oxygen concentration
|
21%(standardcondition)Oxygen
concentration can affectsensitivity
|
minimum value is
over 2%
|
Sensitivity characteristic
Symbol
|
Parameter name
|
Technical parameter
|
Remarks
|
Rs
|
Sensing Resistance
|
10KΩ- 60KΩ
(1000ppm LPG )
|
Detectingconcentrationscope:
200-10000ppmLPG , iso-butane,propane,
LNG
|
α
(1000ppm/
4000ppm LPG)
|
Concentration slope rate
|
≤0.6
| |
Standard
detectingcondition
|
Temp: 20℃±2℃ Vc:5V±0.1
Humidity: 65%±5% Vh: 5V±0.1
| ||
Preheat time
|
Over24 hour
|
Structure and configuration, basic measuring circuit
APPLICATIONS
• Gas leak detection system
• Fire/Safety detection system
• Gas leak alarm
• Gas detector
• Fire/Safety detection system
• Gas leak alarm
• Gas detector